Test your CSMS
ChargeBench plays the charger. Our simulated charge point connects to your CSMS over OCPP 1.6J and runs 100+ backend cases. Nothing to install on your side.
What you enter
- WebSocket URL — the address chargers use to reach your CSMS, for example
wss://your-csms.example.com/ocpp/. ChargeBench adds the charge box ID to the end, as a real charger does. - Charge box ID — the charge point identity to connect as. Register the same ID in your CSMS first, so it accepts the connection.
- Connection password (optional) — if your CSMS asks chargers for HTTP Basic authentication, enter the password you set for this charge box ID.
What runs
Each case sends real OCPP 1.6J messages (BootNotification, Authorize, StartTransaction, MeterValues, StatusNotification and more) and checks that your CSMS answers correctly and in time. Some cases also check what your CSMS sends to the charge point, such as RemoteStartTransaction or ChangeConfiguration.
When we ask you to act
Some cases need your CSMS to send a command, for example "start a charging session remotely". The run then pauses and shows a box with the step. Do it in your own CSMS, then click Done. If your CSMS cannot do it, click Skip: the run moves on and that case shows what was missing.
Your report
When the run ends, open it from Reports. The HTML report lists every case with pass or fail, the messages exchanged and a hint for each failure. ChargeBench is an independent compatibility test, not an OCA certification.
Common problems
- Cannot connect — the URL is wrong or not reachable from the internet, or your CSMS rejects unknown charge box IDs.
- 401 / auth failed — the connection password does not match what your CSMS expects.
- BootNotification not Accepted — register the charge box ID in your CSMS and set it to accept new chargers.